Er12 on a Cool Energy heat pump: Discharge temperature too high

Short answer

On a Cool Energy heat pump, Er12 means: Discharge temperature too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the ecoTech DC Inverter (R32 EVI)

The manual says: Discharge temperature too high.

On the Inverter range CE-iH (R410A, c.2020)

The manual says: Modular board fault.

On the Pro Range CE-H (fixed-speed)

The manual says: Compressor high discharge temperature.

When it shows: Discharge temperature >=115C for 30 s (p.24).

Likely causes:

  • Insufficient refrigerant charge.
  • Discharge temperature sensor faulty.
  • PC board damaged.

Is it safe?

On the ecoTech DC Inverter (R32 EVI)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Inverter range CE-iH (R410A, c.2020)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Pro Range CE-H (fixed-speed)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Resumes after 3 minutes (p.24).

What you can check

On the ecoTech DC Inverter (R32 EVI)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

On the Inverter range CE-iH (R410A, c.2020)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is switched on (do not repeatedly reset if it trips).

On the Pro Range CE-H (fixed-speed)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

What the engineer will check

On the ecoTech DC Inverter (R32 EVI)

  • Check water flow first (high pressure is often caused by low flow).
  • Check refrigerant pressures/temperatures with gauges (F-gas qualified).
  • Check for refrigerant leak or blockage, EEV operation and pressure switches/transducers.

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification (Category I) for refrigerant circuit work.

On the Inverter range CE-iH (R410A, c.2020)

  • Check compressor windings and wiring/phase sequence.
  • Check inverter drive parameters match compressor model.
  • Check operating envelope (flow, pressures, load).

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification; electrical competence.

On the Pro Range CE-H (fixed-speed)

  • Recharge to label volume.
  • Replace discharge sensor.
  • Replace PC board.
  • Check water flow first (high pressure is often caused by low flow).
  • Check refrigerant pressures/temperatures with gauges (F-gas qualified).
  • Check for refrigerant leak or blockage, EEV operation and pressure switches/transducers.

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification (Category I) for refrigerant circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.