Er03 on a Cool Energy heat pump: Insufficient water flow

Short answer

On a Cool Energy heat pump, Er03 means: Insufficient water flow. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the ecoTech DC Inverter (R32 EVI)

The manual says: Insufficient water flow.

On the Inverter range CE-iH (R410A, c.2020)

The manual says: Supply Water Probe Fault.

On the Pro Range CE-H (fixed-speed)

The manual says: Water flow switch fault (troubleshooting table 'Error code 03'; not in common code table).

Likely causes:

  • Water flow switch faulty.
  • Connection cable damaged or disconnected.
  • Controller / PC board faulty.

Is it safe?

On the ecoTech DC Inverter (R32 EVI)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Clears when flow restored (p.33).

On the Inverter range CE-iH (R410A, c.2020)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Pro Range CE-H (fixed-speed)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

On the ecoTech DC Inverter (R32 EVI)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.

On the Inverter range CE-iH (R410A, c.2020)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.

On the Pro Range CE-H (fixed-speed)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.

What the engineer will check

On the ecoTech DC Inverter (R32 EVI)

  • Check water flow rate/flow switch and wiring.
  • Check strainer/magnetic filter for blockage.
  • Vent air from the system.
  • Check circulating pump operation and pipe sizing.
  • Check valves/zone valves are open.

Who to ask for: heating / plumbing heat pump installer.

Certification: None specific (unvented/G3 if cylinder work).

On the Inverter range CE-iH (R410A, c.2020)

  • Check the named sensor/probe connection at the PCB (loose/oxidised plug).
  • Measure sensor resistance against the manufacturer table and replace if faulty.
  • Check controller/PCB if sensor is good.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence.

On the Pro Range CE-H (fixed-speed)

  • Replace water flow switch; if no flow switch installed check terminal is linked out.
  • Replace/reconnect cable.
  • Replace PC board/controller.
  • Check water flow rate/flow switch and wiring.
  • Check strainer/magnetic filter for blockage.
  • Vent air from the system.
  • Check circulating pump operation and pipe sizing.
  • Check valves/zone valves are open.

Who to ask for: heating / plumbing heat pump installer.

Certification: None specific (unvented/G3 if cylinder work).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026