Er06 on a Cool Energy heat pump: Ambient temperature probe fault

Short answer

On a Cool Energy heat pump, Er06 means: Ambient temperature probe fault. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Inverter range CE-iH (R410A, c.2020)

The manual says: Ambient temperature probe fault.

On the Pro Range CE-H (fixed-speed)

The manual says: Compressor low pressure and/or faulty switch.

When it shows: Low pressure; not checked during defrost or first 5 min (p.24).

Likely causes:

  • Refrigerant leakage.
  • LP switch control cable damaged/disconnected.
  • LP switch cannot be reset.
  • Sensor input shorted.
  • Refrigeration system blocked.

Is it safe?

On the Inverter range CE-iH (R410A, c.2020)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Pro Range CE-H (fixed-speed)

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Resumes 3 min after reset.

Manual reset: Permanently disabled after 3 occurrences in 1 hour.

What you can check

On the Inverter range CE-iH (R410A, c.2020)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.

On the Pro Range CE-H (fixed-speed)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

What the engineer will check

On the Inverter range CE-iH (R410A, c.2020)

  • Check the named sensor/probe connection at the PCB (loose/oxidised plug).
  • Measure sensor resistance against the manufacturer table and replace if faulty.
  • Check controller/PCB if sensor is good.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence.

On the Pro Range CE-H (fixed-speed)

  • Detect and repair leak, vacuum and recharge.
  • Replace cable/LP switch/PC board.
  • Clear blockage and re-vacuum.
  • Check water flow first (high pressure is often caused by low flow).
  • Check refrigerant pressures/temperatures with gauges (F-gas qualified).
  • Check for refrigerant leak or blockage, EEV operation and pressure switches/transducers.

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification (Category I) for refrigerant circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.