Heat pumps · Error codes · Cool Energy
Er34Cool Energy
Er34 on a Cool Energy heat pump: The temperature of inverter driver module is too high
Short answer
On a Cool Energy heat pump, Er34 means: The temperature of inverter driver module is too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.
Reviewed 23 September 2026 · 2 sources
What it means
On the ecoTech DC Inverter (R32 EVI)
The manual says: The temperature of inverter driver module is too high.
On the Inverter range CE-iH (R410A, c.2020)
The manual says: Compressor speed abnormal.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
What you can check
- Read and note the code shown on the controller display, then contact your installer or service engineer.
- Check the heat pump's breaker/isolator at the consumer unit is switched on (do not repeatedly reset if it trips).
What the engineer will check
- Check compressor windings and wiring/phase sequence.
- Check inverter drive parameters match compressor model.
- Check operating envelope (flow, pressures, load).
Who to ask for: refrigeration / F-gas heat pump engineer.
Certification: F-gas certification; electrical competence.
What you might notice
Sources
- Cool Energy ecoTech Monoblock Series R32 EVI Heat Pump Water Heaters - Installation and Users Guide v2.1 (2022) ↗ · Version 2.1 · page 31 · Reviewed 23 September 2026
- Cool Energy Inverter Monoblock Series Heat Pump Water Heaters - Installation and Users Guide Version 5 ↗ · Version 5 · page 22 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026