Heat pumps · Error codes · Cool Energy
Er33Cool Energy
Er33 on a Cool Energy heat pump: Coil temperature too high
Short answer
On a Cool Energy heat pump, Er33 means: Coil temperature too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.
Reviewed 23 September 2026 · 2 sources
What it means
On the ecoTech DC Inverter (R32 EVI)
The manual says: Coil temperature too high.
On the Inverter range CE-iH (R410A, c.2020)
The manual says: Compressor Starts Loose.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
What you can check
On the ecoTech DC Inverter (R32 EVI)
- Read and note the code shown on the controller display, then contact your installer or service engineer.
- Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
- Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.
On the Inverter range CE-iH (R410A, c.2020)
- Read and note the code shown on the controller display, then contact your installer or service engineer.
- Check the heat pump's breaker/isolator at the consumer unit is switched on (do not repeatedly reset if it trips).
What the engineer will check
On the ecoTech DC Inverter (R32 EVI)
- Check water flow rate and temperature sensors.
- Check set-points and system design temperatures.
- Check refrigerant charge.
Who to ask for: heat pump engineer.
Certification: None specific.
On the Inverter range CE-iH (R410A, c.2020)
- Check compressor windings and wiring/phase sequence.
- Check inverter drive parameters match compressor model.
- Check operating envelope (flow, pressures, load).
Who to ask for: refrigeration / F-gas heat pump engineer.
Certification: F-gas certification; electrical competence.
What you might notice
Sources
- Cool Energy ecoTech Monoblock Series R32 EVI Heat Pump Water Heaters - Installation and Users Guide v2.1 (2022) ↗ · Version 2.1 · page 31 · Reviewed 23 September 2026
- Cool Energy Inverter Monoblock Series Heat Pump Water Heaters - Installation and Users Guide Version 5 ↗ · Version 5 · page 22 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026