Er33 on a Cool Energy heat pump: Coil temperature too high

Short answer

On a Cool Energy heat pump, Er33 means: Coil temperature too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the ecoTech DC Inverter (R32 EVI)

The manual says: Coil temperature too high.

On the Inverter range CE-iH (R410A, c.2020)

The manual says: Compressor Starts Loose.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

On the ecoTech DC Inverter (R32 EVI)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

On the Inverter range CE-iH (R410A, c.2020)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is switched on (do not repeatedly reset if it trips).

What the engineer will check

On the ecoTech DC Inverter (R32 EVI)

  • Check water flow rate and temperature sensors.
  • Check set-points and system design temperatures.
  • Check refrigerant charge.

Who to ask for: heat pump engineer.

Certification: None specific.

On the Inverter range CE-iH (R410A, c.2020)

  • Check compressor windings and wiring/phase sequence.
  • Check inverter drive parameters match compressor model.
  • Check operating envelope (flow, pressures, load).

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification; electrical competence.