Er16Cool Energy

Er16 on a Cool Energy heat pump: Evaporator coil temperature sensor fault

Short answer

On a Cool Energy heat pump, Er16 means: Evaporator coil temperature sensor fault. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the ecoTech DC Inverter (R32 EVI)

The manual says: Evaporator coil temperature sensor fault.

On the Pro Range CE-H (fixed-speed)

The manual says: Faulty Evaporator sensor.

Likely causes:

  • Defrost (evaporator) temperature sensor faulty.
  • Sensor plug disconnected/oxidised.
  • Controller/PC board faulty.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.

What the engineer will check

On the ecoTech DC Inverter (R32 EVI)

  • Check the named sensor/probe connection at the PCB (loose/oxidised plug).
  • Measure sensor resistance against the manufacturer table and replace if faulty.
  • Check controller/PCB if sensor is good.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence.

On the Pro Range CE-H (fixed-speed)

  • Replace or reconnect/clean sensor.
  • Replace controller/PC board.
  • Check the named sensor/probe connection at the PCB (loose/oxidised plug).
  • Measure sensor resistance against the manufacturer table and replace if faulty.
  • Check controller/PCB if sensor is good.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.