SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Carrier
E3Carrier · AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

E3 on a Carrier AquaSnap / AquaSnap Plus 30AWH: NUI communication failure: NUI has not received CCN communications for 60 s; temperature display shows E3, time area '-', outside temp blanked

Short answer

On a Carrier heat pump, E3 means: NUI communication failure: NUI has not received CCN communications for 60 s; temperature display shows E3, time area '-', outside temp blanked. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: NUI communication failure: NUI has not received CCN communications for 60 s; temperature display shows E3, time area '-', outside temp blanked.

Part involved: NUI 33AW-CS1.

Likely causes:

  • Communication cable fault between NUI and outdoor unit.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

What you can check

  • Note the code/LED pattern and the model from the rating plate, then contact a heat pump/refrigeration engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is on.

What the engineer will check

  • Check communication cable between NUI and outdoor unit.

Who to ask for: refrigeration / heat pump engineer.

Certification: Electrical competence for work inside the unit.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026