9 on a Carrier heat pump: Flow switch error / water pump

Short answer

On a Carrier heat pump, 9 means: Flow switch error / water pump. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

The manual says: Flow switch error / water pump.

Likely causes:

  • Insufficient water flow, pump fault, air, blocked strainer.

On the AquaSnap Plus 30AWH (R410A monobloc)

The manual says: Flow Switch error / Water Pump.

Likely causes:

  • Manual lists: check drain pump winding resistance.
  • check float switch status/functionality (as printed).

Is it safe?

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the AquaSnap Plus 30AWH (R410A monobloc)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

  • Note the code/LED pattern and the model from the rating plate, then contact a heat pump/refrigeration engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Check the heating system pressure gauge reads in the normal range stated by the installer (usually about 1-1.5 bar cold) and that the filling loop is closed.

On the AquaSnap Plus 30AWH (R410A monobloc)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Read the system pressure gauge and report the reading to your engineer (manuals ask for more than 1 bar when cold).
  • Check the filling loop valves are closed.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

What the engineer will check

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

  • Check pump, flow switch, strainer, valves, water volume and antifreeze setting.

Who to ask for: refrigeration / heat pump engineer.

Certification: Electrical competence for work inside the unit.

On the AquaSnap Plus 30AWH (R410A monobloc)

  • Manual lists: check drain pump winding resistance.
  • check float switch status/functionality (as printed).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026