24 on a Carrier heat pump: Outdoor fan motor error

Short answer

On a Carrier heat pump, 24 means: Outdoor fan motor error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

The manual says: Outdoor fan motor error.

Likely causes:

  • Fan motor fault or obstruction.

On the AquaSnap Plus 30AWH (R410A monobloc)

The manual says: Outdoor Fan motor error.

Likely causes:

  • Defective detection of position.
  • over-current protective circuit of outdoor fan driving unit operates.
  • outdoor fan locked.
  • check the inverter board.

Is it safe?

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the AquaSnap Plus 30AWH (R410A monobloc)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

  • Note the code/LED pattern and the model from the rating plate, then contact a heat pump/refrigeration engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Check the outdoor unit is not blocked by leaves, snow or debris.

On the AquaSnap Plus 30AWH (R410A monobloc)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Check the outdoor unit is not blocked by leaves, debris or snow and has clear space around it.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

What the engineer will check

On the AquaSnap / AquaSnap Plus 30AWH (R410A inverter monobloc, 2010-2018 generations)

  • Check fan motor and drive.

Who to ask for: refrigeration / heat pump engineer.

Certification: Electrical competence for work inside the unit.

On the AquaSnap Plus 30AWH (R410A monobloc)

  • Defective detection of position.
  • over-current protective circuit of outdoor fan driving unit operates.
  • outdoor fan locked.
  • check the inverter board.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.