Solar · Error codes · Solis
StateSolis · S6-GR1P-S single-phase string inverter

State on a Solis S6-GR1P-S single-phase string inverter: G100 State 2 excursion - export current exceeded the G100 backflow limit

Short answer

On a Solis inverter, State means: G100 State 2 excursion - export current exceeded the G100 backflow limit. The inverter keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: G100 State 2 excursion - export current exceeded the G100 backflow limit.

Part involved: G100 export limitation (UK).

Likely causes:

  • Current flow exceeded 'G100V2 Backflow Current' in G100 scenarios (export limit breached).

Is it safe?

Does the inverter stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter keeps running with some functions stopped.

Resetting itself: no.

Manual reset: G100 requires manual reset: Settings > EPM Setting > Built-in EPM Setting > G100V2 Alarm Clear.

What you can check

  • Read the full code and message on the inverter screen or in the SolisCloud app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).
  • This is a UK export-limit (ENA G100) alarm that must be manually reset - ask your installer, who should also check why the export limit was exceeded.

What the engineer will check

  • Reset via EPM menu after finding cause (CT position/ direction, meter, limit setting).

Who to ask for: Qualified electrician / MCS PV installer.

Certification: Export limitation scheme per ENA EREC G100; installer responsible for configuration.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026