SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · SolaX Power
IE:00063SolaX Power · SolaX X1-Mini G4 (0.6-4.0 kW)

IE:00063 on a SolaX Power SolaX X1-Mini G4: METER Fault

Short answer

On a SolaX Power inverter, IE:00063 means: METER Fault. The inverter keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: METER Fault.

Part involved: Energy meter / CT clamp communication.

Likely causes:

  • Meter not connected / CT fallen off.

Is it safe?

Does the inverter stop?Partly
SeverityWarning
Engineer needed?Yes

The inverter keeps running with some functions stopped.

Resetting itself: yes - clears when communication is restored.

Manual reset: no.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Check the meter's display is lit (look only).
  • Note any recent electrical work near the meter/consumer unit.
  • Where the SolaX manual says 'press the ESC key to restart the inverter', a homeowner can do that on the display. Steps that say 'disconnect PV+/PV-/battery' are for the installer only.

What the engineer will check

  • Check meter RS485/Modbus wiring polarity and termination.
  • Check CT orientation (arrow towards grid/house per manual) and seating.
  • Check meter address/baud settings.
  • Check export-limit setting (G99) - some inverters stop if export control is on and meter lost.

Who to ask for: PV/battery installer.

Certification: Installer or electrician for meter/CT/comms cabling; homeowner can handle Wi-Fi/router issues.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026