SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · SMA Solar Technology AG
3601SMA Solar Technology AG · Sunny Boy (SB 1.5-6.0)

3601 on a SMA Solar Technology AG Sunny Boy: The leakage current of the inverter and the PV module is too high. There is a ground fault, a residual current or a malfunction. The inverter interrupts feed-in operation immediately after exceeding a threshold. When the fault is eliminated, the inverter automatically reconnects to the utility grid

Short answer

On a SMA Solar Technology AG inverter, 3601 means: The leakage current of the inverter and the PV module is too high. There is a ground fault, a residual current or a malfunction. The inverter interrupts feed-in operation immediately after exceeding a threshold. When the fault is eliminated, the inverter automatically reconnects to the utility grid. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: The leakage current of the inverter and the PV module is too high. There is a ground fault, a residual current or a malfunction. The inverter interrupts feed-in operation immediately after exceeding a threshold. When the fault is eliminated, the inverter automatically reconnects to the utility grid.

Part involved: insulation / residual current (earth fault).

When it shows: The leakage current of the inverter and the PV module is too high. There is a ground fault, a residual current or a malfunction. The inverter interrupts feed-in operation immediately after exceeding a threshold. When the fault is eliminated, the inverter automatically reconnects to the utility grid.

Likely causes:

  • SMA corrective measures: Check the PV system for ground faults.

Is it safe?

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Automatic when condition clears.

What you can check

  • Read the event number and message in the SMA Energy app / Sunny Portal (ennexOS) or the inverter's web interface and note the date/time for your installer. A red LED on the inverter means an event has occurred.
  • Do not touch the panels, cables or inverter enclosure - an earth (ground) fault may make exposed parts live. Contact your installer.
  • Note whether it happens mainly after rain or in the morning dew - this helps the installer.

What the engineer will check

  • Check the PV system for ground faults per SMA section 'Checking the PV System for Ground Faults' (insulation resistance measurement per string, damaged cables/connectors, water ingress, module defects); check any RCD type/setting.

Who to ask for: MCS PV installer with insulation-resistance test equipment.

Certification: Qualified electrician (BS 7671; MCS-certified PV installer for work on the PV array/DC side).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026