2067 on a Huawei SUN2000-L1 single-phase hybrid-ready inverter: Smart power sensor (meter) disconnected (Major)

Short answer

On a Huawei inverter, 2067 means: Smart power sensor (meter) disconnected (Major). The inverter keeps running with some functions stopped.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Smart power sensor (meter) disconnected (Major).

Part involved: smart power sensor / meter.

Likely causes:

  • Meter disconnected, wrong model configured, RS485 parameters mismatch.

Is it safe?

Does the inverter stop?Partly
SeverityWarning

The inverter keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: Clears when meter comms restored.

What you can check

  • Read the full code and message on the inverter screen or in the FusionSolar app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).

What the engineer will check

  • Check meter model configured, RS485 parameters, meter power and cable.

Who to ask for: Qualified electrician / MCS PV installer.

Certification: Battery and hybrid-inverter DC work: installer trained/approved by the manufacturer; electrical work under BS 7671 by a competent person.