Solar · Error codes · GoodWe Technologies Co., Ltd.
15GoodWe Technologies Co., Ltd. · GoodWe ET / ET Plus+ (5-10 kW)

15 on a GoodWe Technologies Co., Ltd. GoodWe ET / ET Plus+: PV overvoltage - String open-circuit voltage higher than max DC input voltage

Short answer

On a GoodWe Technologies Co., Ltd. inverter, 15 means: PV overvoltage - String open-circuit voltage higher than max DC input voltage. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: PV overvoltage - String open-circuit voltage higher than max DC input voltage.

Part involved: DC input.

Likely causes:

  • String open-circuit voltage higher than max DC input voltage. | Troubleshooting: Measure string DC voltage; reduce modules per string; check temperature coefficient (EZ designer).

Is it safe?

Does the inverter stop?Yes
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Restart per GoodWe troubleshooting guide.

What you can check

  • Check the inverter LEDs (FAULT LED on = fault) and read the alarm in the SEMS Portal app or SolarGo app; note code, message and time for your installer.
  • Contact your installer - common on very cold bright mornings if strings are over-sized.

What the engineer will check

  • Measure Voc; redesign string.

Who to ask for: GoodWe-trained installer / MCS PV & battery installer.

Certification: Qualified electrician (BS 7671; MCS-certified PV installer for work on the PV array/DC side).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026