Solar · Error codes · GoodWe Technologies Co., Ltd.
11GoodWe Technologies Co., Ltd. · GoodWe ET / ET Plus+ (5-10 kW)

11 on a GoodWe Technologies Co., Ltd. GoodWe ET / ET Plus+: DC bus high - Internal DC bus voltage too high

Short answer

On a GoodWe Technologies Co., Ltd. inverter, 11 means: DC bus high - Internal DC bus voltage too high. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: DC bus high - Internal DC bus voltage too high.

Part involved: DC bus.

Likely causes:

  • Internal DC bus voltage too high; PV voltage exceeds inverter maximum; PV current leaking to ground. | Troubleshooting: Restart; confirm PV voltage in range; measure PV+/PV- to ground (>30 kOhm); contact service.

Is it safe?

Does the inverter stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Restart per GoodWe troubleshooting guide.

What you can check

  • Check the inverter LEDs (FAULT LED on = fault) and read the alarm in the SEMS Portal app or SolarGo app; note code, message and time for your installer.
  • GoodWe's first step for this code is a restart. Ask your installer to talk you through it or do it - GoodWe's guide is written for installers and the power-down sequence involves the DC switch and battery.

What the engineer will check

  • Check string Voc vs max input; insulation resistance; service.

Who to ask for: GoodWe-trained installer / MCS PV & battery installer.

Certification: Qualified electrician (BS 7671; MCS-certified PV installer for work on the PV array/DC side).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026