Solar · Error codes · GoodWe Technologies Co., Ltd.
10GoodWe Technologies Co., Ltd. · GoodWe ET / ET Plus+ (5-10 kW)

10 on a GoodWe Technologies Co., Ltd. GoodWe ET / ET Plus+: Ground I failure - Neutral & ground not well connected on AC terminals

Short answer

On a GoodWe Technologies Co., Ltd. inverter, 10 means: Ground I failure - Neutral & ground not well connected on AC terminals. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Ground I failure - Neutral & ground not well connected on AC terminals.

Part involved: earth/leakage current.

Likely causes:

  • Neutral & ground not well connected on AC terminals; PV leakage to ground in high humidity; utility ground loss. | Troubleshooting: Check N-PE voltage (~0 V); if only on humid days it is PV panel leakage.

Is it safe?

Does the inverter stop?Yes
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Restart per GoodWe troubleshooting guide.

What you can check

  • Check the inverter LEDs (FAULT LED on = fault) and read the alarm in the SEMS Portal app or SolarGo app; note code, message and time for your installer.
  • Note whether it only happens on wet/humid days and tell your installer.

What the engineer will check

  • Measure earth-to-frame voltage; check N/PE terminations; insulation test on PV.

Who to ask for: GoodWe-trained installer / MCS PV & battery installer.