Solar · Error codes · Enphase Energy
dc-resistance-low-power-offEnphase Energy · Enphase IQ8 microinverters (IQ8MC/IQ8AC/IQ8HC UK)

dc-resistance-low-power-off on an Enphase Energy Enphase IQ8 microinverters: Microinverter insulation-resistance sensor measured PV+ or PV- to earth below ~7 kOhm; it stops producing and shows solid red LED

Short answer

On an Enphase Energy inverter, dc-resistance-low-power-off means: Microinverter insulation-resistance sensor measured PV+ or PV- to earth below ~7 kOhm; it stops producing and shows solid red LED. The inverter keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Microinverter insulation-resistance sensor measured PV+ or PV- to earth below ~7 kOhm; it stops producing and shows solid red LED.

Part involved: microinverter IR sensor / PV module insulation.

When it shows: Microinverter insulation-resistance sensor measured PV+ or PV- to earth below ~7 kOhm; it stops producing and shows solid red LED.

Likely causes:

  • Defective module insulation, defective wiring or connectors, moisture ingress or similar.

Is it safe?

Does the inverter stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter keeps running with some functions stopped.

Resetting itself: no.

Manual reset: Cleared remotely by the installer via Enphase Installer Platform (Events > DC Resistance Low - Power Off > device > Tasks > Clear GFI); clears only if the cause is gone.

What you can check

  • Open the Enphase App (or Enlighten) and note the event name, affected microinverter serial number(s) and date/time for your installer.
  • Only the affected panel(s) stop; the rest of the system keeps generating.
  • Contact your installer - the reset is done remotely through the installer platform.

What the engineer will check

  • Clear via Installer Platform; if it returns, measure PV+ and PV- to earth on module and microinverter (anything below ~7 kOhm trips it); swap faulty module or microinverter.

Who to ask for: Enphase-certified installer / MCS PV installer.

Certification: Qualified electrician (BS 7671; MCS-certified PV installer for work on the PV array/DC side).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026