Tripped-low-pressure-switch on a Worcester Bosch Greensource air to water heat pump: Alarm window: Tripped low pressure switch

Short answer

On a Worcester Bosch heat pump, Tripped-low-pressure-switch means: Alarm window: Tripped low pressure switch. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm window: Tripped low pressure switch.

Part involved: low pressure switch.

When it shows: Evaporator blocked; fan blocked; refrigerant fault in circuit; faulty defrost system or fan motor (4-way valve, defrost settings); faulty expansion valve.

Likely causes:

  • Evaporator blocked; fan blocked; refrigerant fault in circuit; faulty defrost system or fan motor (4-way valve, defrost settings); faulty expansion valve.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Select Acknowledge on the control panel (manual says there is never a risk in resetting an alarm); heat pump restarts within ~15 min if there is demand. Call the installer if the alarm recurs.

What you can check

  • Read and note the full alarm text shown on the controller and pass it to your installer.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).
  • Select Acknowledge on the control panel (manual says there is never a risk in resetting an alarm); heat pump restarts within ~15 min if there is demand. Call the installer if the alarm recurs.

What the engineer will check

  • Check refrigerant charge and tightness, 4-way valve, defrost settings, fan motor, expansion valve.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026