SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Worcester Bosch
P4Worcester Bosch · Bosch Compress 2000 AWF (R32 all-in-one monobloc)

P4 on a Worcester Bosch Bosch Compress 2000 AWF: Alarm table: Exhaust air temperature overheating protection Tp / Troubleshooting table: Protection for high discharge temperature

Short answer

On a Worcester Bosch heat pump, P4 means: Alarm table: Exhaust air temperature overheating protection Tp / Troubleshooting table: Protection for high discharge temperature. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm table: Exhaust air temperature overheating protection Tp / Troubleshooting table: Protection for high discharge temperature.

Part involved: Tp discharge temperature.

When it shows: Exhaust air temperature overheating protection Tp.

Likely causes:

  • As P1; insufficient refrigerant; TW_out, T1 or T5 sensor loose.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Manual 13.2: switch the unit off and on again to reset the safety device; if reset fails contact dealer. Manual 11.4 warns repeated resets can cause irreversible damage.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Manual 13.2: one off/on restart may be tried; if the code returns, stop and call an engineer - repeated resets can damage the unit.

What the engineer will check

  • Check refrigerant charge, sensor seating, then P1 checks.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • Keeps stopping / cutting out on the Bosch Compress 2000 AWF (R32 all-in-one monobloc): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026