SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Worcester Bosch
E4Worcester Bosch · Bosch Compress 2000 AWF (R32 all-in-one monobloc)

E4 on a Worcester Bosch Bosch Compress 2000 AWF: Alarm table: Storage tank water temperature sensor T5 failure / Troubleshooting table: T5 DHW temperature sensor error

Short answer

On a Worcester Bosch heat pump, E4 means: Alarm table: Storage tank water temperature sensor T5 failure / Troubleshooting table: T5 DHW temperature sensor error. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm table: Storage tank water temperature sensor T5 failure / Troubleshooting table: T5 DHW temperature sensor error.

Part involved: T5 DHW cylinder sensor.

When it shows: Storage tank water temperature sensor T5 failure.

Likely causes:

  • Sensor connector loose, wet/water ingress in connector, or sensor faulty (manual: reconnect, dry and seal connector with waterproof adhesive, or replace sensor).

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: Manual 13.2: switch the unit off and on again to reset the safety device; if reset fails contact dealer. Manual 11.4 warns repeated resets can cause irreversible damage.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Manual 13.2: one off/on restart may be tried; if the code returns, stop and call an engineer - repeated resets can damage the unit.

What the engineer will check

  • Check sensor connector seating and moisture; measure sensor resistance; replace sensor if faulty (inside unit casing - isolate power, wait 10 min for DC bus discharge).

Who to ask for: heat pump installer / electrician.

Certification: Electrical work to BS 7671 by competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026