Heat pumps · Error codes · Worcester Bosch
P1Worcester Bosch · Bosch Compress 2000 AWF (R32 all-in-one monobloc)

P1 on a Worcester Bosch Bosch Compress 2000 AWF: Alarm table: Discharge temperature/high pressure control switch protection / Troubleshooting table: High pressure protection

Short answer

On a Worcester Bosch heat pump, P1 means: Alarm table: Discharge temperature/high pressure control switch protection / Troubleshooting table: High pressure protection. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm table: Discharge temperature/high pressure control switch protection / Troubleshooting table: High pressure protection.

Part involved: high pressure protection.

When it shows: Discharge temperature/high pressure control switch protection.

Likely causes:

  • Heating/DHW: low water flow/high water temperature, air in system, water pressure below 0.1 MPa, refrigerant quantity issue, EEV blocked/connector loose; DHW: cylinder coil area insufficient (increase dT1S5); Cooling: coil cover fitted, dirty/obstructed coil, insufficient clearances/ventilation, fan faults.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Manual 13.2: switch the unit off and on again to reset the safety device; if reset fails contact dealer. Manual 11.4 warns repeated resets can cause irreversible damage.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Check the heating system pressure gauge reading (Bosch guidance is typically 1-2 bar when cold); report low pressure to your installer.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).
  • Manual 13.2: one off/on restart may be tried; if the code returns, stop and call an engineer - repeated resets can damage the unit.

What the engineer will check

  • Vent and repressurise to 0.15-0.18 MPa, check flow, check refrigerant charge and EEV, adjust DHW parameters, clear coil and clearances.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • Keeps stopping / cutting out on the Bosch Compress 2000 AWF (R32 all-in-one monobloc): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026