Heat pumps · Error codes · Worcester Bosch
H6Worcester Bosch · Bosch Compress 2000 AWF (R32 all-in-one monobloc)

H6 on a Worcester Bosch Bosch Compress 2000 AWF: Alarm table: DC fan failure / Troubleshooting table: DC fan error

Short answer

On a Worcester Bosch heat pump, H6 means: Alarm table: DC fan failure / Troubleshooting table: DC fan error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm table: DC fan failure / Troubleshooting table: DC fan error.

Part involved: DC fan motor.

When it shows: DC fan failure.

Likely causes:

  • Strong wind forcing fan to rotate in reverse (reorient unit or fit guard); faulty fan motor.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Manual 13.2: switch the unit off and on again to reset the safety device; if reset fails contact dealer. Manual 11.4 warns repeated resets can cause irreversible damage.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).
  • Manual 13.2: one off/on restart may be tried; if the code returns, stop and call an engineer - repeated resets can damage the unit.

What the engineer will check

  • Check fan motor and wind exposure; replace motor.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026