H1 on a Worcester Bosch Bosch Compress 2000 AWF: Alarm table: Communication error between unit and IR341 (unit and inverter module) / Troubleshooting table: Communication error between PCB A inverter module and the main PCB B control board

Short answer

On a Worcester Bosch heat pump, H1 means: Alarm table: Communication error between unit and IR341 (unit and inverter module) / Troubleshooting table: Communication error between PCB A inverter module and the main PCB B control board. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm table: Communication error between unit and IR341 (unit and inverter module) / Troubleshooting table: Communication error between PCB A inverter module and the main PCB B control board.

Part involved: inverter module to main PCB.

When it shows: Communication error between unit and IR341 (unit and inverter module).

Likely causes:

  • Power not connected to PCB/secondary board (indicator light off); loose/broken wire between main and secondary PCB; faulty boards.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Manual 13.2: switch the unit off and on again to reset the safety device; if reset fails contact dealer. Manual 11.4 warns repeated resets can cause irreversible damage.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Manual 13.2: one off/on restart may be tried; if the code returns, stop and call an engineer - repeated resets can damage the unit.

What the engineer will check

  • Check board power and indicator; check interconnecting wiring; replace main PCB and secondary board.

Who to ask for: heat pump installer / electrician.

Certification: Electrical work to BS 7671 by competent person.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • Heat pump will not start on the Bosch Compress 2000 AWF (R32 all-in-one monobloc): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.