E8Worcester Bosch · Bosch Compress 2000 AWF (R32 all-in-one monobloc)

E8 on a Worcester Bosch Bosch Compress 2000 AWF: Alarm table: Water flow failure (displayed three times and can be reset after minutes) / Troubleshooting table: Water flow-rate error

Short answer

On a Worcester Bosch heat pump, E8 means: Alarm table: Water flow failure (displayed three times and can be reset after minutes) / Troubleshooting table: Water flow-rate error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm table: Water flow failure (displayed three times and can be reset after minutes) / Troubleshooting table: Water flow-rate error.

Part involved: water flow / circulation.

When it shows: Water flow failure (displayed three times and can be reset after minutes).

Likely causes:

  • Shut-off valves not fully open; dirty water filter; air in system; water pressure below 1 bar; pump speed not at maximum; expansion tank failure; circuit resistance too high for pump; during defrost - backup heater supply/fuses; pump fuse or PCB fuse blown.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Manual 13.2: switch the unit off and on again to reset the safety device; if reset fails contact dealer. Manual 11.4 warns repeated resets can cause irreversible damage.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Check the heating system pressure gauge reading (Bosch guidance is typically 1-2 bar when cold); report low pressure to your installer.
  • Manual 13.2: one off/on restart may be tried; if the code returns, stop and call an engineer - repeated resets can damage the unit.

What the engineer will check

  • Open valves, clean filter, vent system, repressurise to >1 bar, set pump speed, check expansion vessel, check backup heater supply and fuses, check pump and PCB fuses.

Who to ask for: heat pump installer / heating engineer.

Certification: None specific for hydraulic checks; MCS-certified installer recommended for system changes.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • Keeps stopping / cutting out on the Bosch Compress 2000 AWF (R32 all-in-one monobloc): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026