F17 on a Trianco heat pump: Temperature fault of drive board
Short answer
On a Trianco heat pump, F17 means: Temperature fault of drive board. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.
Reviewed 23 September 2026 · 3 sources
What it means
On the Activair High Temperature R290 (5/9/15/22kW)
The manual says: Temperature fault of drive board.
Part involved: temperature sensor/thermistor.
Likely causes:
- Heat sink temperature sensor fault.
On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)
The manual says: Comp. Driver Temp. Sensor Fault.
Part involved: temperature sensor/thermistor.
Likely causes:
- The transducer is overheat.
On the Activair Pro (AI) R290 6/12/17kW
The manual says: Compressor Driver Temperature Sensor Fault.
Part involved: temperature sensor/thermistor.
Likely causes:
- Driver temperature sensor fault or overtemperature condition.
Is it safe?
| Does the heat pump stop? | Not stated |
|---|---|
| Engineer needed? | Yes |
The manual does not say whether the heat pump stops.
What you can check
- Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
- Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
What the engineer will check
On the Activair High Temperature R290 (5/9/15/22kW)
- Check the connection of heat sink temp sensor.
- Check its resistance.
- If OK, replace heat sink and heat sink temp sensor.
Who to ask for: heat pump controls / electrical.
Certification: Competent heat pump engineer; electrical competence for work inside the unit.
On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)
- Check and adjust the current measurement.
Who to ask for: heat pump controls / electrical.
Certification: Competent heat pump engineer; electrical competence for work inside the unit.
On the Activair Pro (AI) R290 6/12/17kW
- Check and calibrate the temperature sensing circuit.
Who to ask for: heat pump controls / electrical.
Certification: Competent heat pump engineer; electrical competence for work inside the unit.
What you might notice
Sources
- Trianco Activair High Temperature Air Source Heat Pump (R290 5/9/15/22kW) - Installation Operation and Service Manual ↗ · November 2024 (PDF regenerated 2026-08) · page 36 · Reviewed 23 September 2026
- Trianco Activair R290 High Temperature Indoor Air Source Heat Pump (3.2kW wall hung) - Installation Operation and Service Manual ↗ · 2026-08 · page 34 · Reviewed 23 September 2026
- Trianco Activair Pro Air Source Heat Pump (R290 6/12/17kW) - Installation Operation and Service Manual ↗ · 06/2026 · page 42 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026