E01 on a Trianco heat pump: High Pressure Protection

Short answer

On a Trianco heat pump, E01 means: High Pressure Protection. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: High Pressure Protection.

Part involved: pressure switch / compressor discharge-suction.

Likely causes:

  • High pressure switch is damaged or false connected.
  • Scaling of casing or plate heat exchanger (heating).
  • Fins dirty and blocked, poor ventilation (cooling).
  • Abnormal throttling.
  • System blocking.
  • Outlet water temperature on the high side.
  • Excessive refrigerant charge.

On the Activair R410A indoor wall hung 3kW (S300)

The manual says: High pressure protection (exhaust pressure is high, high pressure switch action).

Part involved: pressure switch / compressor discharge-suction.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the outdoor unit is not blocked by debris/snow and has its required clearances.

What the engineer will check

On the Activair High Temperature R290 (5/9/15/22kW)

  • Investigate high pressure switch, heat exchanger and refrigerant system per listed causes.

Who to ask for: refrigeration.

Certification: F-gas certified refrigeration engineer (REFCOM or equivalent).

On the Activair R410A indoor wall hung 3kW (S300)

  • Check the high-pressure switch or check if the refrigerant system is blocked.

Who to ask for: refrigeration.

Certification: F-gas certified refrigeration engineer (REFCOM or equivalent).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026