E03Trianco

E03 on a Trianco heat pump: Water Flow switch Protection

Short answer

On a Trianco heat pump, E03 means: Water Flow switch Protection. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: Water Flow switch Protection.

Part involved: water flow / water temperature.

Likely causes:

  • Water pump failure.
  • Water system not completely emptied of gas (air).
  • Resistance of the water system too large.
  • Valves of the water system not fully opened.
  • Water circuit filter dirty and blocked.
  • Water flow switch false connected or damaged.

On the Activair R410A indoor wall hung 3kW (S300)

The manual says: Water flow failure (no water or little water in water system).

Part involved: water flow / water temperature.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the heating system pressure gauge reading (if one is fitted) and tell your engineer if it is below the level set at commissioning; do not attempt to refill unless you have been shown how.

What the engineer will check

On the Activair High Temperature R290 (5/9/15/22kW)

  • Check flow switch and water pump per listed causes.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer (manufacturer training recommended).

On the Activair R410A indoor wall hung 3kW (S300)

  • Check the flow volume, water pump is failure or not.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer (manufacturer training recommended).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026