E12 on a Trianco heat pump: Syst1: Low Pressure Prot

Short answer

On a Trianco heat pump, E12 means: Syst1: Low Pressure Prot. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the Activair Commercial R290 50kW (FG9550)

The manual says: Syst1: Low Pressure Prot.

Part involved: pressure switch / compressor discharge-suction.

Likely causes:

  • The low-voltage (low-pressure) switch of the system is disconnected.

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: LP Protection.

Part involved: pressure switch / compressor discharge-suction.

Likely causes:

  • LP switch is open.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

The manual says: LP Fault.

Part involved: pressure switch / compressor discharge-suction.

Likely causes:

  • The low-pressure switch is broken.

On the Activair Pro (AI) R290 6/12/17kW

The manual says: LP Fault.

Part involved: pressure switch / compressor discharge-suction.

Likely causes:

  • The low-pressure switch is broken.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the outdoor unit is not blocked by debris/snow and has its required clearances.

What the engineer will check

On the Activair Commercial R290 50kW (FG9550)

  • Inspect System 1 pressure switch and refrigerating circuit for any failure.

Who to ask for: refrigeration.

Certification: F-gas certified refrigeration engineer (REFCOM or equivalent).

On the Activair High Temperature R290 (5/9/15/22kW)

  • Check whether showing the error after unit shutdown.
  • Measure the suction pressure when the unit is running.
  • Detect EEV step, discharge pressure, inlet/outlet water, discharge and suction temp.
  • Release all the gas of the system and refill refrigerant according to the nameplate.

Who to ask for: refrigeration.

Certification: F-gas certified refrigeration engineer (REFCOM or equivalent).

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

  • Check the pressure switch and cold circuit.

Who to ask for: refrigeration.

Certification: F-gas certified refrigeration engineer (REFCOM or equivalent).

On the Activair Pro (AI) R290 6/12/17kW

  • Check the pressure switch and cold circuit.

Who to ask for: refrigeration.

Certification: F-gas certified refrigeration engineer (REFCOM or equivalent).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026