F10Trianco

F10 on a Trianco heat pump: Communication Failure between DSP and PFC

Short answer

On a Trianco heat pump, F10 means: Communication Failure between DSP and PFC. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: Communication Failure between DSP and PFC.

Part involved: controller/PCB communication.

Likely causes:

  • Only in single phase unit.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

The manual says: AC Power Overvoltage Fault.

Part involved: compressor driver / inverter board.

Likely causes:

  • Input voltage > Input overload-voltage protection value.

On the Activair Pro (AI) R290 6/12/17kW

The manual says: AC Power Overvoltage Fault.

Part involved: compressor driver / inverter board.

Likely causes:

  • Input voltage exceeds the overvoltage protection threshold.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

On the Activair High Temperature R290 (5/9/15/22kW)

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the controller display is lit and showing the code.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).

On the Activair Pro (AI) R290 6/12/17kW

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).

What the engineer will check

On the Activair High Temperature R290 (5/9/15/22kW)

  • Check the inverter board connection.
  • If no problem, replace compressor driver board.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

  • Check whether the input voltage is higher than 265V.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

On the Activair Pro (AI) R290 6/12/17kW

  • Verify that the input voltage is not higher than 265 V.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026