F08Trianco

F08 on a Trianco heat pump: AC Input Over current

Short answer

On a Trianco heat pump, F08 means: AC Input Over current. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: AC Input Over current.

Part involved: compressor driver / inverter board.

Likely causes:

  • AC input over current (single phase unit only).

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

The manual says: AC Power Overcurrent Fault.

Part involved: compressor driver / inverter board.

Likely causes:

  • The input voltage is too high, more than outage protection current RMS.

On the Activair Pro (AI) R290 6/12/17kW

The manual says: AC Power Overcurrent Fault.

Part involved: compressor driver / inverter board.

Likely causes:

  • Input current exceeds the RMS overcurrent protection limit.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).

What the engineer will check

On the Activair High Temperature R290 (5/9/15/22kW)

  • Restart the unit.
  • Check if there is electric leakage.
  • If not, replace the drive board.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

  • Check the input voltage measurement.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

On the Activair Pro (AI) R290 6/12/17kW

  • Check the input voltage measurement.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026