F01 on a Trianco heat pump: Compressor activation failure

Short answer

On a Trianco heat pump, F01 means: Compressor activation failure. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: Compressor activation failure.

Part involved: compressor driver / inverter board.

Likely causes:

  • Compressor failed to start.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

The manual says: Comp. Driver Fault.

Part involved: compressor driver / inverter board.

Likely causes:

  • Lack of phase, step or drive hardware damage.

On the Activair Pro (AI) R290 6/12/17kW

The manual says: Compressor Driver Fault.

Part involved: compressor driver / inverter board.

Likely causes:

  • Phase loss, drive step fault, or driver hardware damage.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).

What the engineer will check

On the Activair High Temperature R290 (5/9/15/22kW)

  • Restart the unit.
  • Check EEV step, high/low pressure, inlet/outlet water temp.
  • Check U/V/W connection between compressor and driver board.
  • Check compressor resistance.
  • Check compressor driver board.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

  • Check the measuring voltage.
  • check frequency conversion board hardware.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

On the Activair Pro (AI) R290 6/12/17kW

  • Check voltage measurements and inspect the inverter board hardware.

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.