SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Samsung
E474Samsung

E474 on a Samsung heat pump: [Inverter] IPM Heat Sink Error

Short answer

On a Samsung heat pump, E474 means: [Inverter] IPM Heat Sink Error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

The manual says: [Inverter] IPM Heat Sink Error.

Part involved: Inverter PCB / compressor.

When it shows: Unit self-diagnosis: [Inverter] IPM Heat Sink Error.

Likely causes:

  • Inverter/compressor drive fault: supply voltage issue, compressor wiring/winding, IPM/PFC/sensor fault on inverter PCB, refrigerant or airflow problem causing overcurrent/overheat.
  • Engineer checks per Samsung service manual: Check heatsink assembly; exchange inverter PBA.

On the EHS Mono R32 (AE***RXYD*G)

The manual says: IPM(IGBT Module) or PFCM temperature sensor Error.

Part involved: Inverter PCB / compressor.

When it shows: Unit self-diagnosis: IPM(IGBT Module) or PFCM temperature sensor Error.

Likely causes:

  • Inverter/compressor drive fault: supply voltage issue, compressor wiring/winding, IPM/PFC/sensor fault on inverter PCB, refrigerant or airflow problem causing overcurrent/overheat.
  • Engineer checks per Samsung service manual: Check heatsink assembly; exchange inverter PBA.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; check the outdoor unit is not blocked by leaves, debris or snow and air can flow freely; then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

  • Check heatsink assembly; exchange inverter PBA. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer with electrical and refrigeration competence; R290 (A3 flammable refrigerant) competence.

Certification: Competent electrical worker (BS 7671); F-gas certification if refrigerant circuit is opened; R290/flammable refrigerant handling training (e.g. hydrocarbon refrigerant course).

On the EHS Mono R32 (AE***RXYD*G)

  • Check heatsink assembly; exchange inverter PBA. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer with electrical and refrigeration competence.

Certification: Competent electrical worker (BS 7671); F-gas certification if refrigerant circuit is opened.

What you might notice

What owners and engineers report

9 owner and engineer reports mention this.

  • No heating on the EHS Mono R32 (AE***RXYD*G): 6 reports
  • Keeps stopping / cutting out on the EHS Mono R32 (AE***RXYD*G): 2 reports
  • Intermittent fault on the EHS Mono R32 (AE***RXYD*G): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026