Heat pumps · Error codes · Samsung
E121Samsung

E121 on a Samsung heat pump: Error of ROOM Temperature Sensor in Indoor unit short/open

Short answer

On a Samsung heat pump, E121 means: Error of ROOM Temperature Sensor in Indoor unit short/open. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

The manual says: Error of ROOM Temperature Sensor in Indoor unit short/open.

Part involved: Room temperature sensor / thermostat input.

When it shows: Unit self-diagnosis: Error of ROOM Temperature Sensor in Indoor unit short/open.

Likely causes:

  • Room temperature sensor/thermostat input short or open circuit, wiring or configuration fault.
  • Engineer checks per Samsung service manual: Check the Zone 1 room temperature sensor/thermostat and hydro unit PCB connector (CNS043 per SM).

On the EHS Mono R32 (AE***RXYD*G)

The manual says: Short- or open-circuit error of the room temperature sensor of the Zone 1 indoor unit (detected only when the room thermostat is used).

Part involved: Room temperature sensor / thermostat input.

When it shows: Unit self-diagnosis: Short- or open-circuit error of the room temperature sensor of the Zone 1 indoor unit (detected only when the room thermostat is used).

Likely causes:

  • Room temperature sensor/thermostat input short or open circuit, wiring or configuration fault.
  • Engineer checks per Samsung service manual: Check the Zone 1 room temperature sensor/thermostat and hydro unit PCB connector (CNS043 per SM).

On the EHS TDM Plus (R410A)

The manual says: Error on indoor temperature sensor of indoor unit (Short or Open).

Part involved: Room temperature sensor / thermostat input.

When it shows: Unit self-diagnosis: Error on indoor temperature sensor of indoor unit (Short or Open).

Likely causes:

  • Room temperature sensor/thermostat input short or open circuit, wiring or configuration fault.
  • Engineer checks per Samsung service manual: Check the Zone 1 room temperature sensor/thermostat and hydro unit PCB connector (CNS043 per SM).

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; check thermostat/timer and controller operating-mode settings; then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

  • Check the Zone 1 room temperature sensor/thermostat and hydro unit PCB connector (CNS043 per SM). Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer (controls).

Certification: None specific (low-voltage controls).

What you might notice

What owners and engineers report

15 owner and engineer reports mention this.

  • Controller / thermostat problem on the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K): 2 reports
  • Controller / thermostat problem on the EHS Mono R32 (AE***RXYD*G): 7 reports
  • No heating on the EHS Mono R32 (AE***RXYD*G): 6 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026