E468 on a Samsung heat pump: [Inverter] Comp Current Sensor Error

Short answer

On a Samsung heat pump, E468 means: [Inverter] Comp Current Sensor Error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

The manual says: [Inverter] Comp Current Sensor Error.

Part involved: Inverter PCB / compressor.

When it shows: Unit self-diagnosis: [Inverter] Comp Current Sensor Error.

Likely causes:

  • Inverter/compressor drive fault: supply voltage issue, compressor wiring/winding, IPM/PFC/sensor fault on inverter PCB, refrigerant or airflow problem causing overcurrent/overheat.
  • Engineer checks per Samsung service manual: Check EEPROM data and normal operation of inverter PCB (exchange inverter PBA if faulty).

On the EHS Mono R32 (AE***RXYD*G)

The manual says: [Inverter] Current sensor error.

Part involved: Inverter PCB / compressor.

When it shows: Unit self-diagnosis: [Inverter] Current sensor error.

Likely causes:

  • Inverter/compressor drive fault: supply voltage issue, compressor wiring/winding, IPM/PFC/sensor fault on inverter PCB, refrigerant or airflow problem causing overcurrent/overheat.
  • Engineer checks per Samsung service manual: Check EEPROM data and normal operation of inverter PCB (exchange inverter PBA if faulty).

On the EHS Split Generation 4 (AEX/AEN, 2014)

The manual says: Current sensor error.

Part involved: Inverter PCB / compressor.

When it shows: Unit self-diagnosis: Current sensor error.

Likely causes:

  • Inverter/compressor drive fault: supply voltage issue, compressor wiring/winding, IPM/PFC/sensor fault on inverter PCB, refrigerant or airflow problem causing overcurrent/overheat.
  • Engineer checks per Samsung service manual: Check EEPROM data and normal operation of inverter PCB (exchange inverter PBA if faulty).

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; check the outdoor unit is not blocked by leaves, debris or snow and air can flow freely; then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

  • Check EEPROM data and normal operation of inverter PCB (exchange inverter PBA if faulty). Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer with electrical and refrigeration competence; R290 (A3 flammable refrigerant) competence.

Certification: Competent electrical worker (BS 7671); F-gas certification if refrigerant circuit is opened; R290/flammable refrigerant handling training (e.g. hydrocarbon refrigerant course).

On the EHS Mono R32 (AE***RXYD*G)

  • Check EEPROM data and normal operation of inverter PCB (exchange inverter PBA if faulty). Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer with electrical and refrigeration competence.

Certification: Competent electrical worker (BS 7671); F-gas certification if refrigerant circuit is opened.

On the EHS Split Generation 4 (AEX/AEN, 2014)

  • Check EEPROM data and normal operation of inverter PCB (exchange inverter PBA if faulty). Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer with electrical and refrigeration competence.

Certification: Competent electrical worker (BS 7671); F-gas certification if refrigerant circuit is opened.

What you might notice

What owners and engineers report

9 owner and engineer reports mention this.

  • No heating on the EHS Mono R32 (AE***RXYD*G): 6 reports
  • Keeps stopping / cutting out on the EHS Mono R32 (AE***RXYD*G): 2 reports
  • Intermittent fault on the EHS Mono R32 (AE***RXYD*G): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.