E443Samsung

E443 on a Samsung heat pump: No startup due to Low pressure

Short answer

On a Samsung heat pump, E443 means: No startup due to Low pressure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

The manual says: No startup due to Low pressure.

Part involved: Compressor / refrigerant cycle protection.

When it shows: Unit self-diagnosis: No startup due to Low pressure.

Likely causes:

  • Compressor stopped by refrigerant-cycle protection (pressure, discharge temperature, overload or compression ratio): e.g. refrigerant under/overcharge, blockage, poor water flow or airflow, sensor fault.
  • Engineer checks per Samsung service manual: Check refrigerant leakage/shortage and disconnection or breakdown of pressure sensor(s).

On the EHS Mono (R410A, AE***JXYD*H)

The manual says: Gas leakage error (before operating).

Part involved: Compressor / refrigerant cycle protection.

When it shows: Unit self-diagnosis: Gas leakage error (before operating).

Likely causes:

  • Compressor stopped by refrigerant-cycle protection (pressure, discharge temperature, overload or compression ratio): e.g. refrigerant under/overcharge, blockage, poor water flow or airflow, sensor fault.
  • Engineer checks per Samsung service manual: Check refrigerant leakage/shortage and disconnection or breakdown of pressure sensor(s).

On the EHS TDM Plus (R410A)

The manual says: Operation prohibited due to low pressure.

Part involved: Compressor / refrigerant cycle protection.

When it shows: Unit self-diagnosis: Operation prohibited due to low pressure.

Likely causes:

  • Compressor stopped by refrigerant-cycle protection (pressure, discharge temperature, overload or compression ratio): e.g. refrigerant under/overcharge, blockage, poor water flow or airflow, sensor fault.
  • Engineer checks per Samsung service manual: Check refrigerant leakage/shortage and disconnection or breakdown of pressure sensor(s).

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; check the outdoor unit is not blocked by leaves, debris or snow and air can flow freely; check the heating system pressure gauge reading (typically 1-2 bar when cold; do not top up unless you have been shown how); then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

  • Check refrigerant leakage/shortage and disconnection or breakdown of pressure sensor(s). Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: F-gas certified refrigeration/heat pump engineer; R290 (A3 flammable refrigerant) competence.

Certification: F-gas certification (UK F-gas Regulation; e.g. City & Guilds 2079 Cat I); R290/flammable refrigerant handling training (e.g. hydrocarbon refrigerant course).

On the EHS Mono (R410A, AE***JXYD*H)

  • Check refrigerant leakage/shortage and disconnection or breakdown of pressure sensor(s). Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: F-gas certified refrigeration/heat pump engineer.

Certification: F-gas certification (UK F-gas Regulation; e.g. City & Guilds 2079 Cat I).

On the EHS TDM Plus (R410A)

  • Check refrigerant leakage/shortage and disconnection or breakdown of pressure sensor(s). Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: F-gas certified refrigeration/heat pump engineer.

Certification: F-gas certification (UK F-gas Regulation; e.g. City & Guilds 2079 Cat I).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026