E441 on a Samsung heat pump: Forbid Cooling Mode when Outdoor Temperature is Low 10°C
Short answer
On a Samsung heat pump, E441 means: Forbid Cooling Mode when Outdoor Temperature is Low 10°C. The heat pump keeps running with some functions stopped. The wording differs by model range — each is shown below.
Reviewed 23 September 2026 · 4 sources
What it means
On the EHS Mono HT Quiet (AE***BXYD*G)
The manual says: Forbid Cooling Mode when Outdoor Temperature is Low 10°C.
Part involved: Operating range control (outdoor temperature).
When it shows: Unit self-diagnosis: Forbid Cooling Mode when Outdoor Temperature is Low 10°C.
Likely causes:
- Operation mode blocked because outdoor temperature is outside the permitted range for that mode; may also be a setting or outdoor sensor fault.
- Engineer checks per Samsung service manual: Check the operation setting state and outdoor temperature sensor.
On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)
The manual says: Forbid Cooling Mode when Outdoor Temperature is Low 10 ℃.
Part involved: Operating range control (outdoor temperature).
When it shows: Unit self-diagnosis: Forbid Cooling Mode when Outdoor Temperature is Low 10 ℃.
Likely causes:
- Operation mode blocked because outdoor temperature is outside the permitted range for that mode; may also be a setting or outdoor sensor fault.
- Engineer checks per Samsung service manual: Check the operation setting state and outdoor temperature sensor.
On the EHS Mono R32 (AE***RXYD*G)
The manual says: Cooling operation blocked (outdoor temperature under 9°C).
Part involved: Operating range control (outdoor temperature).
When it shows: Unit self-diagnosis: Cooling operation blocked (outdoor temperature under 9°C).
Likely causes:
- Operation mode blocked because outdoor temperature is outside the permitted range for that mode; may also be a setting or outdoor sensor fault.
- Engineer checks per Samsung service manual: Check the operation setting state and outdoor temperature sensor.
On the EHS Split Generation 4 (AEX/AEN, 2014)
The manual says: Cooling operation is not available since the outdoor air temperature is lower than -15°C.
Part involved: Operating range control (outdoor temperature).
When it shows: Unit self-diagnosis: Cooling operation is not available since the outdoor air temperature is lower than -15°C.
Likely causes:
- Operation mode blocked because outdoor temperature is outside the permitted range for that mode; may also be a setting or outdoor sensor fault.
- Engineer checks per Samsung service manual: Check the operation setting state and outdoor temperature sensor.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Warning |
The heat pump keeps running with some functions stopped.
Resetting itself: yes - clears when conditions return within range.
Manual reset: not required.
What you can check
- Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; check thermostat/timer and controller operating-mode settings; note the outdoor temperature at the time; the code should clear when temperature returns within range.
What the engineer will check
- Check the operation setting state and outdoor temperature sensor. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.
Who to ask for: Heat pump engineer (only if persistent).
Certification: None specific.
What you might notice
What owners and engineers report
7 owner and engineer reports mention this.
- No heating on the EHS Mono HT Quiet (AE***BXYD*G): 1 report
- No heating on the EHS Mono R32 (AE***RXYD*G): 6 reports
Sources
- EHS R-32 Mono (HT Quiet) Outdoor Unit Installation Manual (EU) DB68-11904A-05 ↗ · DB68-11904A-05 · page p.46 · Reviewed 23 September 2026
- EHS R290 Mono Outdoor Unit Installation Manual AE***CXYD** (EU) DB68-12496A-03 ↗ · DB68-12496A-03 · page p.24 · Reviewed 23 September 2026
- EHS R-32 Mono Outdoor Unit Installation Manual (EU) DB68-08408A-07 ↗ · DB68-08408A-07 · page p.43 · Reviewed 23 September 2026
- Samsung Eco Heating System Service Manual - Outdoor Unit AEX060-160ED*HA / Hydro Unit AEN080/160YD*HA (file RC160MHXGA_SM_E_34513A(1)) ↗ · 34513A(1) · page ManualsLib viewer p.65 (printed p.64) · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026