SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Samsung
E291Samsung

E291 on a Samsung heat pump: High Pressure Sensor Error (open/short)

Short answer

On a Samsung heat pump, E291 means: High Pressure Sensor Error (open/short). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

The manual says: High Pressure Sensor Error (open/short).

Part involved: Refrigerant pressure sensor.

When it shows: Unit self-diagnosis: High Pressure Sensor Error (open/short).

Likely causes:

  • Refrigerant pressure sensor open/short circuit or refrigerant leakage.
  • Engineer checks per Samsung service manual: Check high pressure sensor connection/output; check for refrigerant leakage.

On the EHS TDM Plus (R410A)

The manual says: Refrigerant leakage or error on high pressure sensor (Short or Open).

Part involved: Refrigerant pressure sensor.

When it shows: Unit self-diagnosis: Refrigerant leakage or error on high pressure sensor (Short or Open).

Likely causes:

  • Refrigerant pressure sensor open/short circuit or refrigerant leakage.
  • Engineer checks per Samsung service manual: Check high pressure sensor connection/output; check for refrigerant leakage.

Is it safe?

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

On the EHS TDM Plus (R410A)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

  • Check high pressure sensor connection/output; check for refrigerant leakage. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: F-gas certified refrigeration/heat pump engineer; R290 (A3 flammable refrigerant) competence.

Certification: F-gas certification (UK F-gas Regulation; e.g. City & Guilds 2079 Cat I); R290/flammable refrigerant handling training (e.g. hydrocarbon refrigerant course).

On the EHS TDM Plus (R410A)

  • Check high pressure sensor connection/output; check for refrigerant leakage. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: F-gas certified refrigeration/heat pump engineer.

Certification: F-gas certification (UK F-gas Regulation; e.g. City & Guilds 2079 Cat I).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026