E202 on a Samsung heat pump: CONTROL KIT / Outdoor UNIT Communication Error

Short answer

On a Samsung heat pump, E202 means: CONTROL KIT / Outdoor UNIT Communication Error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the EHS Mono R290 (AE***CXYD*K and pump-integrated AE***CXYB*K)

The manual says: CONTROL KIT / Outdoor UNIT Communication Error.

Part involved: Hydro unit/control kit and outdoor PCB communication.

When it shows: Unit self-diagnosis: CONTROL KIT / Outdoor UNIT Communication Error.

Likely causes:

  • Communication/addressing fault between hydro unit (control kit) and outdoor unit, or between outdoor PCBs: wiring fault, loose connector, incorrect setting, electrical interference or PCB failure.
  • Engineer checks per Samsung service manual: Check communication cable between hydro unit/control kit and outdoor unit; check PCB response LED and measure communication waveform (square wave approx. +/-0.7 V); replace PCB if required.

On the EHS Mono R32 (AE***RXYD*G)

The manual says: CONTROL KIT/OUTDOOR UNIT communication error (3 min).

Part involved: Hydro unit/control kit and outdoor PCB communication.

When it shows: Unit self-diagnosis: CONTROL KIT/OUTDOOR UNIT communication error (3 min).

Likely causes:

  • Communication/addressing fault between hydro unit (control kit) and outdoor unit, or between outdoor PCBs: wiring fault, loose connector, incorrect setting, electrical interference or PCB failure.
  • Engineer checks per Samsung service manual: Check communication cable between hydro unit/control kit and outdoor unit; check PCB response LED and measure communication waveform (square wave approx. +/-0.7 V); replace PCB if required.

On the EHS Split Generation 4 (AEX/AEN, 2014)

The manual says: Abnormal state, no communication between Indoor and Outdoor Main PCB.

Part involved: Hydro unit/control kit and outdoor PCB communication.

When it shows: Unit self-diagnosis: Abnormal state, no communication between Indoor and Outdoor Main PCB.

Likely causes:

  • Communication/addressing fault between hydro unit (control kit) and outdoor unit, or between outdoor PCBs: wiring fault, loose connector, incorrect setting, electrical interference or PCB failure.
  • Engineer checks per Samsung service manual: Check communication cable between hydro unit/control kit and outdoor unit; check PCB response LED and measure communication waveform (square wave approx. +/-0.7 V); replace PCB if required.

On the EHS Split R32 (AE***RXED*G)

The manual says: Hydro Unit / Outdoor Unit communication error(3 min).

Part involved: Hydro unit/control kit and outdoor PCB communication.

When it shows: Unit self-diagnosis: Hydro Unit / Outdoor Unit communication error(3 min).

Likely causes:

  • Communication/addressing fault between hydro unit (control kit) and outdoor unit, or between outdoor PCBs: wiring fault, loose connector, incorrect setting, electrical interference or PCB failure.
  • Engineer checks per Samsung service manual: Check communication cable between hydro unit/control kit and outdoor unit; check PCB response LED and measure communication waveform (square wave approx. +/-0.7 V); replace PCB if required.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

  • Check communication cable between hydro unit/control kit and outdoor unit; check PCB response LED and measure communication waveform (square wave approx. +/-0.7 V); replace PCB if required. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer (Samsung-trained, controls/electrical).

Certification: Competent electrical worker (BS 7671) for work on live equipment.

What you might notice

What owners and engineers report

8 owner and engineer reports mention this.

  • No heating on the EHS Mono R32 (AE***RXYD*G): 6 reports
  • No hot water on the EHS Mono R32 (AE***RXYD*G): 1 report
  • Heat pump will not start on the EHS Mono R32 (AE***RXYD*G): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.