E032 on a Navien PEM750: Flow switch protection (flow switch is open)

Short answer

On a Navien heat pump, E032 means: Flow switch protection (flow switch is open). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Flow switch protection (flow switch is open).

Part involved: flow switch / circulation pump.

Likely causes:

  • Check cable connections, the flow switch, that water valves are fully open, the pump and filter, and air in the water circuit.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

What you can check

  • Note the code shown on the controller and the model number on the unit's rating label before contacting your installer.
  • Check that the heat pump's isolator and consumer-unit breaker are on; do not open any casing.
  • Check the heating system pressure gauge reads within the range your installer set (typically 1-2 bar) and that the filling loop is closed.

What the engineer will check

  • Check the circulation pump runs and the strainer/filter is clean.
  • Vent air from the system.
  • Check the flow switch/flowmeter and its wiring.
  • Check isolation valves are open and minimum flow/volume is met.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026