SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Mitsubishi Heavy Industries Air-Conditioning Europe
E57Mitsubishi Heavy Industries Air-Conditioning Europe · Hydrolution HM gen 1 (HMA100V/HMS140V integrated-controller systems)

E57 on a Mitsubishi Heavy Industries Air-Conditioning Europe Hydrolution HM gen 1: Insufficient refrigerant is detected at initial start-up in cooling mode

Short answer

On a Mitsubishi Heavy Industries Air-Conditioning Europe heat pump, E57 means: Insufficient refrigerant is detected at initial start-up in cooling mode. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Insufficient refrigerant is detected at initial start-up in cooling mode.

Part involved: Low refrigerant.

When it shows: Initial cooling start-up.

Likely causes:

  • Service valve closed; loose connection of sensor (BT15 or BT3); defective sensor (BT15 or BT3); insufficient amount of refrigerant.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: yes (switch SF1 off/on per user manual).

What you can check

  • Note the alarm number/text shown on the display. Check the consumer-unit breakers/isolators for the indoor and outdoor units are on. Check the outdoor unit is not blocked by leaves, snow or ice and its drain is clear (look only - do not open the casing). The user manual allows resetting by switching the indoor unit off and on with switch SF1; if the alarm cannot be reset, hold the operating-mode button to select 'Add. heat only' (immersion heating) and contact the installer. Recurring alarms mean an installation fault.

What the engineer will check

  • Refrigerant-side and PCB checks per HM-T-193 flowchart: check sensor resistances (Tho-R/A/D/S, LPT), 63H1 switch, service valves, refrigerant charge, fan motor and fuse F2, inverter/control PCBs, supply voltage.

Who to ask for: Heat pump / refrigeration engineer (manufacturer-trained).

Certification: F-gas certification for refrigerant-circuit work; electrical competence (Part P/18th Edition) for PCB/wiring.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026