7 on a Mitsubishi Heavy Industries Air-Conditioning Europe Hydrolution HM gen 1: Anti-freeze of heat exchanger; occurs if alarm 72 occurs 3 times within an hour
Short answer
On a Mitsubishi Heavy Industries Air-Conditioning Europe heat pump, 7 means: Anti-freeze of heat exchanger; occurs if alarm 72 occurs 3 times within an hour. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Anti-freeze of heat exchanger; occurs if alarm 72 occurs 3 times within an hour.
Part involved: Anti freeze HX.
When it shows: Alarm 72 x3 within 1 h.
Likely causes:
- Low flow during defrost.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: no.
Manual reset: yes (switch SF1 off/on per user manual).
What you can check
- Note the alarm number/text shown on the display. Check the consumer-unit breakers/isolators for the indoor and outdoor units are on. Check radiator/underfloor thermostats in the house are not all closed (user manual). The user manual allows resetting by switching the indoor unit off and on with switch SF1; if the alarm cannot be reset, hold the operating-mode button to select 'Add. heat only' (immersion heating) and contact the installer. Recurring alarms mean an installation fault.
What the engineer will check
- Indoor-unit checks per HM-T-193 flowchart: check sensors BT12/BT15/BT3, water-side service valves, valves QM31/QN11, strainer, air bleed, circulation pump setting (menu 2.2.5) and relay board AA6; check refrigerant charge/leaks for defrost alarms.
Who to ask for: Heat pump / refrigeration engineer (manufacturer-trained).
Certification: F-gas certification for refrigerant-circuit work; electrical competence (Part P/18th Edition) for PCB/wiring.
What you might notice
Sources
- Technical Manual HM-T-193 - Air to Water Heat Pump (Hydrolution) ↗ · '13 HM-T-193 (updated December 18, 2014) · page ML p.155; flowchart p.164 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026