LB on a Mitsubishi Electric Ecodan: High pressure protection

Short answer

On a Mitsubishi Electric heat pump, LB means: High pressure protection. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: High pressure protection.

Part involved: Plate heat exchanger / heating circuit flow / outdoor unit.

When it shows: High refrigerant pressure detected at FTC.

Likely causes:

  • 1 Flow rate of the heating circuit reduced; 2 Plate heat exchanger clogged; 3 Outdoor unit failure (refrigerant volume, valve, LEV coil, crushed pipe).

Is it safe?

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-resetting; code remains until reset.

Manual reset: Installation manuals: press F4 (RESET) then F3 (Yes) on the main remote controller (older controllers: hold button E for 3 s); 'To cancel error codes please switch system off'. Fix the cause first.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing. Check the primary circuit pressure gauge (typically about 1-2 bar when cold on sealed systems) and look for visible leaks; do not top up or bleed unless your installer has shown you how and the filling loop is then closed.

What the engineer will check

  • 1 Check water circuit; 2 Check plate heat exchanger; 3 Check refrigerant volume, stop valves, LEV coil and pipework of outdoor unit (refer to outdoor service manual).

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R410A) / R32 / R290 as applicable to the outdoor unit.

What you might notice

What owners and engineers report

15 owner and engineer reports mention this.

  • No heating on the Ecodan: 9 reports
  • Keeps stopping / cutting out on the Ecodan: 6 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026