Heat pumps · Error codes · Midea
P4Midea

P4 on a Midea heat pump: Compressor protection against excessively high discharge temperature

Short answer

On a Midea heat pump, P4 means: Compressor protection against excessively high discharge temperature. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: Compressor protection against excessively high discharge temperature.

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: Discharge temperature protection.

Likely causes:

  • Temperature sensor error.
  • High pressure side blockage.
  • Poor condenser heat exchange.
  • Main PCB damaged.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: High discharge temperature protection.

Likely causes:

  • Same causes as P1.
  • refrigerant shortage.
  • TW_out, T1 or T5 sensor loose.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: Discharge temperature protection.

Likely causes:

  • Temperature sensor error.
  • High pressure side blockage.
  • Poor condenser heat exchange.
  • Outdoor unit main PCB damaged.

Is it safe?

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

Does the heat pump stop?Not stated
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

Does the heat pump stop?Not stated
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Check the outdoor unit is not blocked by leaves, debris or snow and has clear space around it.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • Temperature sensor error.
  • High pressure side blockage.
  • Poor condenser heat exchange.
  • Main PCB damaged.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Same causes as P1.
  • refrigerant shortage.
  • TW_out, T1 or T5 sensor loose.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Temperature sensor error.
  • High pressure side blockage.
  • Poor condenser heat exchange.
  • Outdoor unit main PCB damaged.

Sources

A code explains what the controller detected, not a confirmed root cause.