Heat pumps · Error codes · Midea
E2Midea

E2 on a Midea heat pump: Communication fault between user interface and main control PCB

Short answer

On a Midea heat pump, E2 means: Communication fault between user interface and main control PCB. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: Communication fault between user interface and main control PCB.

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: Communication error between outdoor unit and user interface.

Likely causes:

  • Communication wires between outdoor unit and user interface not connected properly.
  • Communication wiring X Y E terminals misconnected.
  • Loosened wiring within electric control box.
  • Interference from high voltage wires or other sources of electromagnetic radiation.
  • Damaged main PCB or electric control box communication terminals block.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: Communication error between user interface and main control board of hydraulic module.

Likely causes:

  • Wire not connected between wired controller and unit.
  • communication wire sequence wrong.
  • strong magnetic field or electrical interference.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: Communication error between the main control board of hydraulic module and user interface.

Likely causes:

  • Communication wires between hydronic box and user interface not connected properly.
  • Communication wiring X Y E terminals misconnected.
  • Loosened wiring within electric control box.
  • Interference from high voltage wires or other sources of electromagnetic radiation.
  • Damaged main PCB or electric control box communication terminals block.

Is it safe?

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • If the breaker has tripped or trips again, leave the unit off and call an engineer; do not keep resetting it.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • If the breaker has tripped or trips again, leave the unit off and call an engineer; do not keep resetting it.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • Communication wires between outdoor unit and user interface not connected properly.
  • Communication wiring X Y E terminals misconnected.
  • Loosened wiring within electric control box.
  • Interference from high voltage wires or other sources of electromagnetic radiation.
  • Damaged main PCB or electric control box communication terminals block.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Wire not connected between wired controller and unit.
  • communication wire sequence wrong.
  • strong magnetic field or electrical interference.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Communication wires between hydronic box and user interface not connected properly.
  • Communication wiring X Y E terminals misconnected.
  • Loosened wiring within electric control box.
  • Interference from high voltage wires or other sources of electromagnetic radiation.
  • Damaged main PCB or electric control box communication terminals block.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026