C7 on a Midea heat pump: Over-high temperature protection for IPM module

Short answer

On a Midea heat pump, C7 means: Over-high temperature protection for IPM module. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: Over-high temperature protection for IPM module.

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: Transducer module temperature too high protection.

Likely causes:

  • See service manual troubleshooting procedure for this code.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: Transducer module temperature too high protect.

Likely causes:

  • Manual: contact your local dealer.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: High temperature protection of transducer (inverter) module.

Likely causes:

  • Power supply voltage of the unit is low.
  • The space between the units is too narrow for heat exchanger.
  • Heat exchanger is dirty or something is block on the surface.
  • Fan is not running.
  • Water flow rate is low.
  • Water outlet temp. sensor is loosen or broken.

Is it safe?

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • If the breaker has tripped or trips again, leave the unit off and call an engineer; do not keep resetting it.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • See service manual troubleshooting procedure for this code.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Manual: contact your local dealer.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Power supply voltage of the unit is low.
  • The space between the units is too narrow for heat exchanger.
  • Heat exchanger is dirty or something is block on the surface.
  • Fan is not running.
  • Water flow rate is low.
  • Water outlet temp. sensor is loosen or broken.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026