HP on a Midea heat pump: Low pressure protection in cooling mode

Short answer

On a Midea heat pump, HP means: Low pressure protection in cooling mode. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: Low pressure protection in cooling mode.

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: Low pressure protection (P0 occurred 3 times) / low pressure protection in cooling.

Likely causes:

  • Low pressure switch not connected properly or has malfunctioned.
  • Insufficient refrigerant.
  • Low pressure side blockage.
  • Poor evaporator heat exchange in heating mode or DHW mode.
  • Insufficient water flow in cooling mode.
  • Main PCB damaged.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: Low pressure protection (Pe<0.6) occurred 3 times in an hour.

Likely causes:

  • Refer to P0.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: Low pressure protection in cooling mode.

Likely causes:

  • Low pressure switch not connected properly or has malfunctioned.
  • Insufficient refrigerant.
  • Low pressure side blockage.
  • Poor evaporator heat exchange in heating mode or DHW mode.
  • Insufficient water flow in cooling mode.
  • Outdoor unit main PCB damaged.

Is it safe?

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Check the outdoor unit is not blocked by leaves, debris or snow and has clear space around it.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • Low pressure switch not connected properly or has malfunctioned.
  • Insufficient refrigerant.
  • Low pressure side blockage.
  • Poor evaporator heat exchange in heating mode or DHW mode.
  • Insufficient water flow in cooling mode.
  • Main PCB damaged.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Refer to P0.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Low pressure switch not connected properly or has malfunctioned.
  • Insufficient refrigerant.
  • Low pressure side blockage.
  • Poor evaporator heat exchange in heating mode or DHW mode.
  • Insufficient water flow in cooling mode.
  • Outdoor unit main PCB damaged.

Sources

A code explains what the controller detected, not a confirmed root cause.