H7 on a Midea heat pump: Power overvoltage and under-voltage protection

Short answer

On a Midea heat pump, H7 means: Power overvoltage and under-voltage protection. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: Power overvoltage and under-voltage protection.

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: Abnormal main circuit voltage.

Likely causes:

  • Power supply voltage not within ±10% of rated voltage or a phase is missing.
  • Outdoor unit powered on immediately after being powered off.
  • Loosened wiring within electric control box.
  • High voltage circuit error.
  • Main PCB damaged.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: Main circuit voltage failure.

Likely causes:

  • Supply voltage outside range.
  • rapid repeated power cycling.
  • main control board circuit defect.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: Abnormal main circuit voltage.

Likely causes:

  • Power supply voltage not within 90%~110% of rated voltage.
  • Outdoor unit main PCB is damaged.

Is it safe?

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • If the breaker has tripped or trips again, leave the unit off and call an engineer; do not keep resetting it.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • Power supply voltage not within ±10% of rated voltage or a phase is missing.
  • Outdoor unit powered on immediately after being powered off.
  • Loosened wiring within electric control box.
  • High voltage circuit error.
  • Main PCB damaged.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Supply voltage outside range.
  • rapid repeated power cycling.
  • main control board circuit defect.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Power supply voltage not within 90%~110% of rated voltage.
  • Outdoor unit main PCB is damaged.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026