H5 on a Midea heat pump: Ta room temperature sensor error

Short answer

On a Midea heat pump, H5 means: Ta room temperature sensor error. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: Ta room temperature sensor error.

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: Room temperature sensor (Ta) error.

Likely causes:

  • Temperature sensor not connected properly or has malfunctioned.
  • Damaged hydronic system main PCB.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: The indoor temperature sensor (Ta) error.

Likely causes:

  • Ta sensor (in the user interface) failed.
  • replace sensor or interface.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: Room temperature sensor (Ta) error.

Likely causes:

  • Temperature sensor not connected properly or has malfunctioned.
  • Damaged hydronic box main PCB.

Is it safe?

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • Temperature sensor not connected properly or has malfunctioned.
  • Damaged hydronic system main PCB.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Ta sensor (in the user interface) failed.
  • replace sensor or interface.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Temperature sensor not connected properly or has malfunctioned.
  • Damaged hydronic box main PCB.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026