Heat pumps · Error codes · Midea
H4Midea

H4 on a Midea heat pump: 3 times of L1* in 60 mins

Short answer

On a Midea heat pump, H4 means: 3 times of L1* in 60 mins. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: 3 times of L1* in 60 mins.

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: Inverter module protection repeated (P6 three times).

Likely causes:

  • See service manual troubleshooting procedure for this code.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: Three times P6 protect.

Likely causes:

  • Same causes as P6.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: P6 appears 3 times in one hour.

Likely causes:

  • See service manual troubleshooting procedure for this code.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • If the breaker has tripped or trips again, leave the unit off and call an engineer; do not keep resetting it.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Restart once via the controller (OFF then ON) as the manual allows; if the code returns, call an engineer.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • See service manual troubleshooting procedure for this code.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Same causes as P6.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • See service manual troubleshooting procedure for this code.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026