F1 on a Midea heat pump: Protection for DC bus undervoltage (1-phase units)

Short answer

On a Midea heat pump, F1 means: Protection for DC bus undervoltage (1-phase units). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

The manual says: Protection for DC bus undervoltage (1-phase units).

Likely causes:

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

The manual says: DC bus voltage too low.

Likely causes:

  • The DC bus voltage is too low.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

The manual says: DC generatrix voltage is too low.

Likely causes:

  • Power supply fault.
  • main board, inverter board, IGBT or rectifier bridge fault.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

The manual says: DC generatrix (DC bus) voltage too low.

Likely causes:

  • The DC generatrix voltage is too low.

Is it safe?

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the exact code shown on the controller display.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • If the breaker has tripped or trips again, leave the unit off and call an engineer; do not keep resetting it.

What the engineer will check

On the M-Thermal Arctic HT R290 monobloc (MHC ...WD2N7)

  • See R290 service manual troubleshooting (section 6) for this code.

On the M-Thermal Mono R32 (MHC ...W/D2N8-B / -B2 'Arctic')

  • The DC bus voltage is too low.

On the M-Thermal Mono R32 compact (MHC ...WD2N8-C, 5/7/9/12/14/16 kW)

  • Power supply fault.
  • main board, inverter board, IGBT or rectifier bridge fault.

On the M-Thermal Split R32 (MHA outdoor + HB hydronic box)

  • The DC generatrix voltage is too low.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026